Troubleshooting and Maintenance 6–2
Table 6.A
Troubleshooting Chart
Problem
Probable Cause(s) Corrective Action(s)
Reader does not power up. No LED indicators
illuminate.
1. Improper connection to power source.
2. Power source not providing 12 to 28
VDC.
1. Check power source.
2. Check for green LED in wiring base.
3. Check the wiring base connector for bent
pins.
No communications with personal computer. 1. Communications fault.
2. No power supply connection at
DeviceNet connector
3. Computer fault.
4. Broken or bent pins on Configuration Port
of Reader
1. Check cable connection.
2. Power must be supplied. See Chapter 3.
3. Refer to computer user manual.
4. Check Configuration Port of Reader for
damaged pins. If pins are damaged, re-
turn Reader.
No laser beam emits from scan window.
1. No laser light trigger signal.
1. Verify Reader Laser Light trigger source
for proper configuration and operation.
Unable to read a label. 1. A label has not been defined.
2. Decoding functions not configured
correctly.
3. Label(s) out of specification.
4. Scan line not on the label.
5. Reader is at incorrect angle or distance
from bar code symbols.
1. Define a label and symbol.
2. Check decoder configuration to verify that
parameters are set appropriately for your
application. After making changes, SEND
the configuration and try again.
3. Use good quality labels that are within
specifications.
4. Reposition the scan line.
5. Use autofocus to adjust the read range.
Use the ON SYMBOL LED to verify that
the Reader is scanning a possible bar
code symbol.
No communications with host. 1. Baud rates not set properly.
2. Loose or incorrect wiring.
3. Broken or bent pins on 24-pin Reader
connector.
4. Reader DeviceNet address or DH485
node and maximum node are not set
properly.
5. Termination switch not set properly.
1. Verify that Reader and host are set at the
same Baud rate.
2. Verify cable connections using connection
diagrams in Chapter 3.
3. Check Reader connector for broken or
bent pins.
4. Verify DeviceNet Address or DH485 node
number settings.
5. Check position of termination switch in
wiring base. Set to correct position.
No communications with network. 1. Communications fault.
2. Loose or incorrect wiring.
3. Broken or bent pins on 24-pin Reader
connector.
4. Reader DeviceNet address or DH485
node and maximum node are not set
properly.
5. Termination switch not set properly.
1. Check status of NETWORK LED, refer to
section “LED Indicators”.
2. Verify cable connections using connection
diagrams in Chapter 3.
3. Check Reader connector for broken or
bent pins.
4. Verify DeviceNet Address or DH485 node
number settings.
5. Check position of termination switch in
wiring base. Set to correct position.
Trou
b
leshoot
i
ng
Chart